supy.util.cal_gs_suewsΒΆ
-
supy.util.
cal_gs_suews
(kd, ta_c, rh, pa, smd, lai, g_cst, g_max, lai_max, wp_smd, debug=False)[source]ΒΆ Model surface conductance/resistance using phenology and atmospheric forcing conditions.
Parameters: - kd (numeric) β Incoming solar radiation [W m-2]
- ta_c (numeric) β Air temperature [degC]
- rh (numeric) β Relative humidity [%]
- pa (numeric) β Air pressure [Pa]
- smd (numeric) β Soil moisture deficit [mm]
- lai (numeric) β Leaf area index [m2 m-2]
- g_cst (size-6 array) β Parameters to determine surface conductance/resistance: g_lai (LAI related), g_kd (solar radiation related), g_dq_base (humidity related), g_dq_shape (humidity related), g_ta (air temperature related), g_smd (soil moisture related)
- g_max (numeric) β Maximum surface conductance [mm s-1]
- lai_max (numeric) β Maximum LAI [m2 m-2]
- wp_smd (numeric) β Wilting point indicated as soil moisture deficit [mm]
Returns: Modelled surface conductance [mm s-1]
Return type: numeric